Part# |
N/A 2601 |
Wire Rope Dia |
N/A 1/2 |
Strand Dia. (in) |
N/A 1/2 |
Std. Take-Up |
N/A 9 |
A T/U Std. |
N/A 17 |
A T/U 48" |
N/A 56 |
A T/U 72" |
N/A 80 |
A T/U 84" |
N/A 92 |
A T/U 96" |
N/A 104 |
B |
N/A 1 1/4 |
C |
N/A 3 3/8 |
d |
N/A 5/8 |
D |
N/A 1 1/4 |
J |
N/A 3 1/8 |
K |
N/A 2 1/8 |
N |
N/A 1 |
TH T/U Std. |
N/A 10 1/2 |
TH T/U 48" |
N/A 49 1/2 |
TH T/U 72" |
N/A 73 1/2 |
TH T/U 84" |
N/A 85 1/2 |
TH T/U 96" |
N/A 97 1/2 |
Q |
N/A 5/8 |
S |
N/A 4 3/4 |
Wt. T/U Std. |
N/A 9 |
Wt. T/U 48" |
N/A 16 |
Wt. T/U 72" |
N/A 19 |
Wt. T/U 84" |
N/A 21 |
Wt. T/U 96" |
N/A 23 |
Material Specification
Sockets up to 4" are ASTM A148 steel, grade 105/85
Sockets above 4" are ASTM A148 steel, grade 115/95
All sockets are magnetic particle inspected at critical areas and proof tested on special order
Tolerances
Dimensions under 4": + 1/8"
Dimensions over 4": + 1/4"
Q (smaller sizes): + 1/32"
D: +0 - 1/32" in a self-colored socket
Note
Dimensions and tolerances shown are prior to galvanize
Cast Sockets are available for use in extreme temperatures; these must be special ordered. * A T/U = A for Take-Up
* E T/U = E for Take-Up
* TH T/U = E for Take-Up
* Wt. T/U = Wt. (lbs) Take-Up
These closed bridge spelter sockets are designed to be installed on to wire rope or aircraft cable.
Sockets up to 4" are ASTM A148 steel, grade 105/85
Sockets above 4" are ASTM A148 steel, grade 115/95
All sockets are magnetic particle inspected at critical areas and proof tested on special order
Tolerances
Dimensions under 4": + 1/8"
Dimensions over 4": + 1/4"
Q (smaller sizes): + 1/32"
D: +0 - 1/32" in a self-colored socket
Note
Dimensions and tolerances shown are prior to galvanize
Cast Sockets are available for use in extreme temperatures; these must be special ordered. * A T/U = A for Take-Up
* E T/U = E for Take-Up
* TH T/U = E for Take-Up
* Wt. T/U = Wt. (lbs) Take-Up
These closed bridge spelter sockets are designed to be installed on to wire rope or aircraft cable.